Wholesale RS485 output temperature humidity controller

Wholesale RS485 output temperature humidity controller
Product Detailed
Related Categories:Temperature Instruments
real time monitoring and control the ambiance relative humidity by control a humidifier or dehumidifier high accuracy                                                                           Wholesale RS485 output temperature humidity controller                         ¨ Temperature Humidity Controller Features

Designed for monitoring andcontrol the ambiance

relative humidity by control a humidifieror

dehumidifier

Temperature detection and controloptional

Microprocessor makesdetection and controlling

   more accurately

Providetwo accuracies types with different

accuracysensors

LCDcan displayworking status such as %RH,

temperature, set point, anddevice mode, etc.

Makes reading andoperating easy and accurate

All models featureuser-friendly setting buttons

Enoughparameters setup let the controller meeting

wide range application. All setup will be held even if

them power failure

  Lock function avoids wrong operation andmakes

setting to be held

  Provideone or two max. 5 amp dry contact outputs.

Infrared Remote Control (optional)

Blue backlight (optional)

RS485 communication interface (optional)

  Externalsensors (optional)

  We alsoprovide other wall mounting and duct mounting humidity controllers, please seethe high accuracy hygrostat THP/TH9-Hygro series and THP –Hygro16 Plug-and-Playhigh-power humidity controller.

¨      Models

 

Product Name

Model

Description

Humidity Controller

Power supply:

-(A)/(B)/(C)

A: 230VAC

B: 110VAC

C: 24 VAC

F2000LB-H1-(C )

Monitoring temperature, setting humidity, 1 ON/OFF triac output to control a humidifier or a dehumidifier.

F2000P-TH-K01-(A)/(B)(C)

Detection temperature and humidity, 1XON/OFF relay output to control a humidifier or dehumidifier. The max. current is up to 5A.

F2000P-TH-K01-a

High accuracy for F2000P-TH-K01

F2000P-TH-K02-(A)/(B)(C)

Detection temperature and humidity, 2 ON/OFF relay outputs to control humidifier/ dehumidifier and a cooling/heating device.

The max. current is up to 5A.

F2000P-TH-K02-a

High accuracy for F2000P-TH-K02

F2000P-TH-K01-WT-(A)/(B)(C)

High accuracy version. Detection temperature and humidity, 1XON/OFF relay output to control a humidifier or dehumidifier., It uses an external compositive digital sensor (WT)

F2000P-TH-K02-WT-(A)/(B)(C)

High accuracy version. Detection temperature and humidity, 2 ON/OFF relay outputs to control humidifier/ dehumidifier and a cooling/heating device. It uses the external compositive digital sensor (WT)

Humidity Controller with RS485 interface

F2000PC-TH-K01-(A)/(B)(C)

High accuracy version. Detection temperature and humidity, 1XON/OFF relay output to control a humidifier or dehumidifier. RS485 communication interface.

F2000PC-TH-K02-(A)/(B)(C)

High accuracy version. Detection temperature and humidity, 2XON/OFF relay outputs to control a humidifier/dehumidifier and a AC device or a fan. RS485 communication interface.

Split Humidity Control Unit

F2000PC-TH-01-TSM-(A)/(B)(C)

Humidity controller with temperature detection, it’s used with a external sensor box (wall mounting type or duct type) together via RS485 connection

F2000PC-TH-02-TSM-(A)/(B)(C)

Temperature &humidity controller , it’s used with a external sensor box (wall mounting type or duct type) together via RS485 connection

External sensor box

F2000TSM-TH-M101-N

Wall mounting external sensor box with the humidity sensor inside.

It must be connected with F2000PC-TH-01-TSM by RS485. The maximum connecting length is 100 meters.

External sensor box

F2000TSM-TH-M201-N

Wall mounting external sensor box with the humidity& temperature sensors inside. It must be connected with F2000PC-TH-02-TSM by RS485. The maximum connecting length is 100 meters.

External sensor box

F2000TSM-TH-D101-N

Duct type of external sensor box with the humidity sensor inside. It can be put into an air duct and must be connected with F2000PC-TH-01-TSM by RS485.

External sensor box

F2000TSM-TH-D201-N

Duct type of external sensor box with the humidity sensor inside. It can be put into an air duct and must be connected with F2000PC-TH-02-TSM by RS485.

Options for Above Models

Accessories

Back light-EL

Blue back light displaying

Remote receiving-R

Remote control humidity with the infrared hand held controller

 

Specifications

 

Power supply

230VAC/110VAC/24VAC   selectable at placing the order

Output

F2000LB-H1: triac resource output

F2000P-TH series: 5A relay for the On/Off output

F2000PC-TH-K01/K02: 5A relay for the On/Off output

Displaying

LCD

Connection length between the controller with the external sensor box

Maximum 100 meters

Net weight of the controller

F2000LB-H1:        230g

F2000P-TH Series:     280g

Dimensions

F2000LB:         120mm(L)×90mm(W)×24mm(H)

F2000P-TH:        120mm(L)×90mm(W)×32mm(H)

Mounting standard

Wall mounting in the wire box of 2”×4” or 65mm×65mm

Sensors spec.

Temperature

Humidity

Accuracy

±0.5°C

±0.4°C-high accuracy version

±5%RH (30%-70%RH)

±4% RH (20%-80%RH)- high accuracy version

Measuring range

0°C~60°C

0~99%RH

0~100%RH-high version

Display resolution

5°C

0.1°C-high version

1% RH

0.1%RH-high version

Stability

±0.1°C

±1%RH per year

Storage environment

10°C-50°C, 10%RH~80%RH

 

 

 

 

 

¨ 